Rapid, secure drug testing using fingerprint development and paper spray mass spectrometry (2017)
Auteur(s) :
COSTA, C. ;
WEBB, R. ;
PALITSIN, V. ;
ISMAIL, M. ;
DE PUIT, M. ;
ATKINSON, S. ;
BAILEY, M. J.
Année
2017
Page(s) :
1745-1752
Langue(s) :
Anglais
Refs biblio. :
30
Domaine :
Drogues illicites / Illicit drugs
Discipline :
PRO (Produits, mode d'action, méthode de dépistage / Substances, action mode, screening methods)
Autres mots-clés
Résumé :
Background: Paper spray mass spectrometry6 is a technique that has recently emerged and has shown excellent analytical sensitivity to a number of drugs in blood. As an alternative to blood, fingerprints have been shown to provide a noninvasive and traceable sampling matrix. Our goal was to validate the use of fingerprint samples to detect cocaine use.
Methods: Samples were collected on triangular pieces (168 mm²) of washed Whatman Grade I chromatography paper. Following application of internal standard, spray solvent and a voltage were applied to the paper before mass spectrometry detection. A fingerprint visualization step was incorporated into the analysis procedure by addition of silver nitrate solution and exposing the sample to ultraviolet light.
Results: Limits of detection for cocaine, benzoylecgonine, and methylecgonine were 1, 2, and 31 ng/mL respectively, with relative standard deviations <33%. No matrix effects were observed. Analysis of 239 fingerprint samples yielded a 99% true-positive rate and a 2.5% false-positive rate, based on the detection of cocaine, benzoylecgonine, or methylecgonine with use of a single fingerprint.
Conclusions: The method offers a qualitative and noninvasive screening test for cocaine use. The analysis method developed is rapid (4 min/sample) and requires no sample preparation.
Methods: Samples were collected on triangular pieces (168 mm²) of washed Whatman Grade I chromatography paper. Following application of internal standard, spray solvent and a voltage were applied to the paper before mass spectrometry detection. A fingerprint visualization step was incorporated into the analysis procedure by addition of silver nitrate solution and exposing the sample to ultraviolet light.
Results: Limits of detection for cocaine, benzoylecgonine, and methylecgonine were 1, 2, and 31 ng/mL respectively, with relative standard deviations <33%. No matrix effects were observed. Analysis of 239 fingerprint samples yielded a 99% true-positive rate and a 2.5% false-positive rate, based on the detection of cocaine, benzoylecgonine, or methylecgonine with use of a single fingerprint.
Conclusions: The method offers a qualitative and noninvasive screening test for cocaine use. The analysis method developed is rapid (4 min/sample) and requires no sample preparation.