• Recherche simple
    • Périodiques
    • Publications OFDT
    • Textes législatifs
    • Nos dernières publications
    • Voir la rubrique recherche
    • Usages de drogues à l’adolescence
    • Usages de drogues féminins
    • Drogues et sécurité routière
    • Addictions en milieu professionnel
    • Addictions en milieu carcéral
    • Voir la rubrique sélections
    • Présentation
    • Contact
    • Voir la rubrique À propos

Entrez vos termes ici. Par défaut, la recherche utilise OU. Ajoutez « + » entre les termes pour une recherche avec ET. Pour plus d'options, consultez la Recherche avancée.

  • Aide
  • Recherche avancée
  • Périodiques

Recherche utilisant l'IA (non conversationnelle - chaque question est indépendante)

  • Aide

Portail documentaire

Site OFDT
Historique
Se connecter
    • Recherche simple
    • Périodiques
    • Publications OFDT
    • Textes législatifs
    • Nos dernières publications
    • Voir la rubrique recherche
    • Usages de drogues à l’adolescence
    • Usages de drogues féminins
    • Drogues et sécurité routière
    • Addictions en milieu professionnel
    • Addictions en milieu carcéral
    • Voir la rubrique sélections
    • Présentation
    • Contact
    • Voir la rubrique À propos
Sélectionner un type de recherche

Entrez vos termes ici. Par défaut, la recherche utilise OU. Ajoutez « + » entre les termes pour une recherche avec ET. Pour plus d'options, consultez la Recherche avancée.

  • Aide
  • Recherche avancée
  • Périodiques

Recherche utilisant l'IA (non conversationnelle - chaque question est indépendante)

  • Aide
  1. Accueil
  2. Retour
Oral fluid collection: the neglected variable in oral fluid testing
Ajouter à la sélection Ajouter à la sélection
Article de Périodique

Oral fluid collection: the neglected variable in oral fluid testing (2005)

Auteur(s) : CROUCH D. J.
Dans : Forensic Science International (Vol.150, n°2-3, 10 June 2005)
Année 2005
Page(s) : 165-173
Sous-type de document : Revue de la littérature / Literature review
Langue(s) : Anglais
Refs biblio. : 31
Domaine : Plusieurs produits / Several products
Discipline : PRO (Produits, mode d'action, méthode de dépistage / Substances, action mode, screening methods)
Thésaurus mots-clés
SALIVE ; TEST ; METHODE ; COHORTE ; ANALYSE CHIMIQUE

Note générale :

Forensic Science International, 2005, 150, (2-3 (Special edition : "Detection of drugs in oral fluids")), 165-173

Résumé :

ENGLISH :
The potential to use oral fluid as a drug-testing specimen has been the subject of considerable scientific interest. The ease with which specimens can be collected and the potential for oral fluid (OF) drug concentrations to reflect blood-drug concentrations make it a potentially valuable specimen in clinical as well as forensic settings. However, the possible effects of the OF collection process on drug detection and quantification has often been over looked. Several studies have documented that drug-contamination of the oral cavity may skew oral fluid/blood drug ratios and confound interpretation when drugs are smoked, insufflated or ingested orally. OF pH is predicted to have an effect on the concentration of drugs in OF. However, in a controlled clinical study, the effect of pH was less than that of collection technique. Mean codeine OF concentrations in specimens collected a non-stimulating control method were 3.6 times higher than those in OF collected after acidic stimulation. Mean codeine concentrations were 50% lower than control using mechanical stimulation and 77% of control using commercial collection devices. Several factors should be considered if a commercial OF collection device is used. In vitro collection experiments demonstrated that the mean collection volume varied between devices from 0.82 to 1.86 mL. The percentage of the collected volume that could be recovered from the device varied from 18% to 83%. In vitro experiments demonstrated considerable variation in the recovery of amphetamines (16-59%), opiates (33-50%), cocaine and benzoylecgonine (61-97%), carboxy-THC (0-53%) and PCP (9-56%). Less variation in collection volume, volume recovered and drug recovery was observed intra-device. The THC stability was evaluated in a common commercial collection protocol. Samples in the collection buffer were relatively stable for 6 weeks when stored frozen. However, stability was marginal under refrigerated conditions and poor at room temperature. Very little has been published on the efficacy of using IgG concentration, or any other endogenous marker, as a measure of OF specimen validity. Preliminary rinsing experiments with moderate (50 mL and 2 x 50 mL) volumes of water did not reduce the OF IgG concentration below proposed specimen validity criteria. In summary, obvious and more subtle variables in the OF collection may have pronounced effects on OF-drug concentrations. This has rarely been acknowledged in the literature, but should to be considered in OF drug testing, interpretation of OF-drug results and future research studies.

Affiliation :

University of Utah, Salt Lake City, UT 84112.
Etats-Unis. United States.
Cote : R00164

Contact

OFDT

69 rue de Varenne
75700 PARIS

Tel : (+33) 01 41 62 77 16

Accès rapides

  • L’établissement
  • Les partenaires
  • La lettre d’information

Avertissement

Toute inclusion dans la base documentaire ne vaut pas crédit scientifique de l'OFDT

Contact

OFDT

69 rue de Varenne
75700 PARIS

Tel : (+33) 01 41 62 77 16

Accès rapides

  • L’établissement
  • Les partenaires
  • La lettre d’information

Avertissement

Toute inclusion dans la base documentaire ne vaut pas crédit scientifique de l'OFDT

Suivez-nous

  • Traitement des données personnelles
  • Mentions légales
  • Plan du site